AssemblePCB
AssemblePCB

Pick-and-Place File for PCB Assembly: Format, Rotation, and Checks

By Published On: November 23, 2026Categories: Blog, PCB Assembly
Pick-and-place file workflow connecting released design data, placement coordinates, visual checks, and an approved assembly package

Table Of Contents

A pick-and-place file tells the assembler where each component belongs, on which board side, and at what exported angle. Before releasing it, verify the revision, coordinate reference, units, rotation convention, population scope, and agreement with the BOM and assembly drawing. A CSV that opens successfully can still describe the wrong build.

For a PCB assembly quotation with AssemblePCB, send placement data with the matching fabrication files, BOM, and orientation notes. Identify unresolved questions so they can be reviewed as part of the build scope rather than silently turned into production assumptions.

Pick-and-place file workflow connecting released design data, placement coordinates, visual checks, and an approved assembly package
The deliverable is a consistent assembly package, not an isolated spreadsheet.

What Is a Pick-and-Place File for PCB Assembly?

A pick-and-place file is a machine-readable component placement list. It is also called a centroid file, CPL, XY file, or placement file. A typical record identifies one reference designator and its X/Y location, rotation, and board side.

The file supports assembly programming; it is not necessarily a ready-to-run machine program. Package mapping, feeder setup, vision recognition, tooling, and process approval remain manufacturing tasks. An angle in a placement export does not, by itself, specify the feeder-tape orientation or the final nozzle command.

Different files answer different manufacturing questions
File Main question What it does not establish alone
BOM Which parts and fitted quantities belong in this variant? The physical placement and orientation of every device.
Pick-and-place / CPL Where is each listed component, and what side and angle are exported? Approved substitute parts, functional performance, or machine readiness.
Gerber and drill files What copper, mask, paste, outline, and holes must be fabricated? A complete, unambiguous component placement list.
Assembly drawing How should the populated board be interpreted visually? A substitute for all structured placement and purchasing data.

These roles can be combined in richer manufacturing formats when supported by the recipient. Confirm the agreed deliverables instead of assuming every assembler requires exactly the same file set.

Pick-and-Place File Format: Fields and a CSV Example

CSV and plain text are common interchange choices. Some suppliers also accept spreadsheets or native manufacturing databases. Confirm the recipient’s template, column names, units, side labels, and delimiter before exporting. Changing a filename extension does not convert the underlying format.

Before sending the file, agree on the coordinate units, position-reference columns, board-side labels, and positive rotation direction. Record these choices in the release notes. A file extension or a familiar column heading does not establish a universal convention for every import system.

Field or accompanying note Example Check before release
Reference designator U3 Unique per board instance; matches the selected assembly variant.
X / Y coordinates 38.000 / 24.000 Known units, origin, axes, and position-reference type.
Rotation 180.0 Degrees, positive direction, zero reference, and side/view convention are understood.
Board side Top Maps explicitly to the receiving software’s layer values.
Footprint / package QFN32 Useful for mapping; not a replacement for the exact BOM part number.
Release identity CTRL-B / Rev C / Variant 2 Shown in the controlled filename, manifest, or agreed header.

An illustrative centroid CSV

This hypothetical five-placement excerpt uses millimeters and a single-board frame. Its column names and angles illustrate data organization; they are not an AssemblePCB import specification or verified component orientations.

Designator,X_mm,Y_mm,Rotation_deg,Side,Footprint
R12,12.000,8.000,0.0,Top,0603_imperial
C8,22.000,8.000,90.0,Top,0805_imperial
U3,38.000,24.000,180.0,Top,QFN32
D5,45.000,10.000,270.0,Top,SOD123
U9,18.000,28.000,0.0,Bottom,SOT23_5

Supply accompanying notes defining the coordinate frame, angle convention, selected variant, and bottom-side treatment. Do not put free-form notes above the header unless the importer supports them. A file can be valid CSV yet fail a supplier’s schema.

Use a decimal point and agreed delimiter. Quote text fields containing delimiters, preserve designators as text, and avoid spreadsheet auto-formatting or rounding. Numerical precision is not placement accuracy. Retain suitable CAD export precision; do not imply that extra decimal places improve the machine or validate the footprint.

Centroid Coordinates: Confirm the Origin and Reference Point

Board origin and footprint reference are different decisions

The board origin locates the coordinate system. The footprint reference determines which point on each component the coordinates describe. A board-wide origin mismatch can move every placement; a footprint-reference mismatch may affect only one package family.

Altium’s assembly-output documentation distinguishes calculated Center X/Y, footprint-reference Ref X/Y, and Pad 1 X/Y. Its calculated center is based on outer pad locations. These columns should not be treated as interchangeable.

Illustrative asymmetric connector with distinct body-center, footprint-origin, and pad-one reference points
Different reference points can be valid data. The importer needs to know which point is being supplied.

For an asymmetric connector or custom footprint, inspect the exported point against the actual land pattern and package drawing. A pad-derived center can differ from a body center. Neither label automatically defines the safe vacuum pickup point; nozzle selection and pickup offsets belong to the assembly process.

Check geometry before editing numbers

Overlay the imported placement data on the released board and assembly information, after accounting for the declared frame. Inspect an asymmetric connector, a polarized part, an off-center device, and each populated side. A center cross alone cannot verify pin orientation or every pad-to-pin relationship.

  • A similar X/Y displacement across many parts suggests an origin or translation issue.
  • A scale mismatch suggests units or import scaling; one inch equals 25.4 mm, while one mil equals 0.0254 mm.
  • An isolated offset suggests a footprint reference, mapping, or individual placement problem.

These are diagnostic clues, not proof of the root cause. Confirm against the released CAD data before applying any correction. Negative coordinates can be legitimate when the origin lies away from the board or a documented side convention uses them.

Pick-and-Place Rotation: Verify Zero Degrees and Polarity

A rotation value is meaningful only with its reference orientation and viewing convention. A component placed at 90° relative to one library footprint can represent the same physical orientation as 0° relative to a differently defined footprint.

Confirm the source footprint’s zero orientation, positive angular direction, board side, and the assembler’s package-library mapping. Do not apply a blanket 90° or 180° spreadsheet correction because a preview looks different. First determine whether the issue belongs to the export, library definition, or import mapping.

Illustrative top-view component rotated counterclockwise from zero to ninety degrees, moving its marked pin-one corner from lower left to lower right
Illustrative convention only: the dot marks the same physical pin-one corner before and after rotation.

Use the manufacturer’s pin numbering and polarity information with the approved assembly drawing. Review IC pin 1, diode cathodes, polarized capacitors, LED polarity, and keyed connectors. Silkscreen is a useful cross-check, but an ambiguous or contradictory marking requires engineering clarification.

A circular centroid marker may look correct even when a diode is reversed. A symmetric package outline may also hide an incorrect orientation. Record the specific device, expected pin or polarity direction, evidence, and approved resolution.

Bottom-side coordinates are not a universal mirror rule

A bottom-side drawing viewed from underneath is visually reversed relative to a through-board top view. That does not mean every exported bottom-side X value must be negated, or every angle must be changed using one fixed formula.

For example, KiCad’s placement exporter has a configurable option to negate bottom-layer X coordinates. Confirm the chosen setting and the receiving system’s expectation. Avoid applying a second mirror after the export or importer has already performed the required transformation.

Check at least an off-center bottom device and a polarized or asymmetric bottom package. If the board has no bottom-side components, state that explicitly rather than supplying an unexplained empty file.

Export from KiCad or Altium Without Losing the Release Context

Export from the released PCB design rather than reconstructing positions manually from a PDF. Menu names and options vary by version; use the official documentation for the installed tool.

KiCad: review the placement-export options

In KiCad 9, the PCB Editor’s File → Fabrication Outputs → Component Placement command provides position-file export. Review format, units, origin, separate or combined sides, bottom-X handling, and component filters. The tool supports excluding DNP footprints and footprints marked to be excluded from position files. Choose settings to match the agreed assembly scope, not a generic screenshot.

Altium Designer: control the assembly output

Use the assembly-output generator or a controlled Output Job. Check the chosen position columns, units, filters, and variant-related output settings. Preview actual records, especially custom footprints. Preserve the output configuration with the project so the next release can be regenerated consistently.

After any board edit that affects component locations, footprints, designators, or population, regenerate the affected outputs as a coherent release. Keep the original export and any approved downstream mapping identifiable; a corrected manufacturing file should not become an undocumented alternative design source.

Eight Checks Before Releasing a Component Placement File

  1. Match the release. Identify board number, revision, variant, export date, and source CAD version. Confirm that BOM and fabrication files belong to the same release.
  2. Test the import. Check required fields, numeric values, delimiter, units, layer labels, and duplicate records. Confirm that all rows import rather than only checking that the file opens.
  3. Compare designator sets. Expand grouped BOM references and compare unique fitted designators within the agreed placement scope. Equal totals alone cannot identify a missing designator replaced by an unintended one.
  4. Explain legitimate exceptions. Separate DNP positions, manual or through-hole assembly, loose accessories, fiducials, and other tooling features. A BOM line may require no automated placement record; a fiducial record may require no purchased component.
  5. Verify the coordinate frame. Confirm origin, units, axis direction, reference-point columns, and board-side handling against the overlay.
  6. Verify orientation. Check polarized and asymmetric devices and any custom or newly mapped package. Inspect pad and pin relationships, not only the centroid.
  7. Confirm panel ownership. State whether the data describes one board or the manufacturing array, and who will generate panel transforms and instance identities.
  8. Close and approve discrepancies. Record the affected references, original finding, responsible owner, approved correction, and release identifier. Define any first-article hold point before the remaining build proceeds.

Example of a misleading count: a hypothetical variant requires 96 automated placements. An incoming file also has 96 rows, but includes R88 instead of required R87. The row count passes; comparison of designator identities fails. Even matching identities would not prove that the positions, parts, or angles are correct.

Single-Board vs Panel Coordinates: A Worked Translation

Tell the assembler whether the placement export describes a single board or an array. If manufacturing engineering will create the panel, avoid expanding every placement yourself without agreement. Otherwise, the receiving workflow could apply a second expansion.

For a hypothetical unrotated board instance, assume U3 is at (38, 24) mm in the local board frame. The instance origin is at (70, 10) mm in the panel frame, with the same axis directions. Translation gives:

Xpanel = 70 + 38 = 108 mm
Ypanel = 10 + 24 = 34 mm

Unrotated panel example showing U3 at local coordinates 38 and 24 millimeters and instance-origin offset 70 and 10, giving panel coordinates 108 and 34
Translation example only. Rotated, flipped, or mixed-orientation instances require the appropriate additional transforms.

This arithmetic checks one coordinate conversion, not panel manufacturability. Confirm image orientation, spacing, rails, tooling, and depaneling separately. When instances rotate, the position vector and component orientation both need the agreed transformation; adding the panel offset alone is insufficient.

For a panel-level file, define how repeated designators are associated with their board instances. Repetition can be valid across instances, while an unexplained duplicate within one instance is a discrepancy. Keep the single-board design identity traceable through the expanded data.

Troubleshooting: Read the Pattern Before Changing the File

Observed pattern Investigate first Useful evidence
Most devices share a similar displacement Different export/import origins or array translation. Declared datum, board outline, and coordinates of several known features.
The placement cloud is the wrong size Inches, millimeters, mils, or an import scale setting. Known physical distances between released coordinates.
Only bottom-side placements are reversed View convention or a duplicate mirror operation. Export settings and an asymmetric bottom-side location.
One connector is offset but nearby passives align Footprint-origin versus center mapping; wrong library package. Pad pattern, package drawing, selected coordinate columns.
Centroids align but several polarized devices face incorrectly Library zero orientation, angle interpretation, or mapping. Pin-one/cathode evidence and the approved assembly drawing.
Rows are missing or unexpected Variant, DNP, export filters, or an incomplete import. Unique reference sets and an explicit exception list.

Keep the source export unchanged while investigating. Once the root cause is understood, correct the design/export configuration or document an approved import transformation. Recheck the entire affected population rather than fixing only the first visible symptom.

Pick-and-Place File FAQs

Is a centroid file the same as a CPL file?

The names commonly describe the same category of placement data. They do not guarantee identical columns, units, or coordinate conventions. Confirm the actual schema.

Can Gerbers and a BOM replace a pick-and-place file?

They do not automatically provide equivalent structured placement information. A supplier may offer data preparation or accept a richer database containing component data. Agree the method, review effort, and orientation verification before relying on it.

Should every component in the BOM appear in the file?

Not necessarily. Define whether the file covers automated placement only, all fitted parts, or a broader programming dataset. Document manual assembly, DNP items, accessories, and fiducials separately so omissions and additions are intentional.

Does a clean placement preview mean the board is ready to build?

No. It provides evidence about imported geometry. It does not establish approved materials, soldering feasibility, electrical function, or completion of every production-release requirement.

Send a Pick-and-Place File That Supports a Clear Assembly Quote

The most useful placement file is reproducible, traceable to the released design, and consistent with the other build documents. Confirm its frame and angle convention, compare designator identities, inspect both sides visually, and close discrepancies before releasing production.

Bring the files together for your next build.

Send AssemblePCB your BOM, fabrication files, pick-and-place export, assembly drawings, quantity per revision, and test requirements. Include export settings and unresolved placement questions. Request a quotation with the manufacturing scope, assumptions, and required approvals identified.

Request a Turnkey PCB Assembly Quote

Contact Us

Phone: +86-18123905375

Email: sales@assemblepcb.com

WhatsApp: +86-18123905375

Wechat: +86-18123905375

Share This Post

Free Queto

Click or drag a file to this area to upload.

Table Of Contents

Contact Us

Phone: +86-18123905375

Email: sales@assemblepcb.com

WhatsApp: +86-18123905375

Wechat: +86-18123905375

Share This Post

Free Queto

Click or drag a file to this area to upload.
Go to Top